EA402 913-402-000-013 A1-E090-F0-G000 Proximity Measurement System

Others
May 09, 2025
Category Connection: Other Brands
Brief: Discover the EA402 913-402-000-013 A1-E090-F0-G000 Proximity Measurement System, a non-contact solution for precise displacement measurement in industrial applications. Ideal for hazardous areas, this system features temperature compensation and high-frequency response.
Related Product Features:
  • Non-contact measurement system based on eddy-current principle.
  • Ex certified for use in hazardous areas (potentially explosive atmospheres).
  • Conforms to API 670 recommendations for reliability.
  • Available in 1, 5, and 10 m system configurations.
  • Temperature-compensated design for accurate readings.
  • Voltage or current output with short circuit protection.
  • Frequency response: DC to 20 kHz (−3 dB) for high precision.
  • Measurement range options: 2 or 4 mm to suit various needs.
Faqs:
  • What is the operating temperature range of the EA402 Proximity Measurement System?
    The system operates effectively in temperatures ranging from −40 to +180 °C.
  • Is the EA402 Proximity Measurement System suitable for hazardous environments?
    Yes, it is Ex certified for use in potentially explosive atmospheres.
  • What are the output options available with this system?
    The system provides voltage or current output, including protection against short circuits.